| Feature Value Filter height 50 cm Extractor height 44 cm Total height 94 cm Filter depth 56 cm Width 62 cm Cold water supply 1/2" Condensate drain to sewer 1" Inlet diameter Ø 150 mm Outlet diameter Ø 140-150 mm Feature | Value |
|---|---|
| Filter height | 50 cm |
| Extractor height | 44 cm |
| Total height | 94 cm |
| Filter depth | 56 cm |
| Width | 62 cm |
| Cold water supply | 1/2" |
| Condensate drain to sewer | 1" |
| Inlet diameter | Ø 150 mm |
| Outlet diameter | Ø 140-150 mm |



Technical Data Sheet
User Manual
HIGH TEMPERATURE
ASPIRATORS
+300°



Code. INOX.4.EBR280


ETC Group S.r.l. Sole Shareholder
Industrial area Pirano, Tavullia
Str. Delle Campagne, 10
61010 Tavullia PU - ITALY
Tel.
+39 0721 1839937
+39 0541 955062
+39 0541 1646150
WhatsApp-web +39 373 7755779
E-Mail DEPARTMENTS
informazioni@etcgroupsrl.biz
commerciale@etcgroupsrl.biz
tecnico@etcgroupsrl.biz
contabilita@etcgroupsrl.biz
VAT and Tax Code: IT 04083110405
Reg. of companies of Pesaro N. REA - PS – 196574
- Scrubbers for Wood-fired Ovens
- Scrubbers for Electric Ovens
- Scrubbers for Charcoal Grills
- Stainless Steel Exhaust Fans
Technical Standards: New UNI 10389-2 and UNI 11859-1

The UNI 10389-2 standard, published in April 2022, defines the procedures for combustion analysis, draft measurement, and fuel moisture determination.
This standard introduces new opportunities for the market, as it finally makes it possible to clearly distinguish clean-combustion systems from polluting systems, for which corrective actions or replacement are required.
At present, particulate matter (dust) analysis is not included in the scope of the standard.
For this reason, installers and maintenance technicians of thermal plants must continue to carry out particulate checks based on their own professional experience, the manufacturers’ instructions, or by relying on specialized chemical laboratories.
The UNI 11859-1 standard provides installers and maintenance personnel with the procedures for inspecting existing flue and exhaust systems, in a manner equivalent to UNI 10845 for gas-fired systems.
Before installation, the installer must verify the suitability of the chimney, for example by applying the requirements of the UNI 11859-1 standard.
The following checks shall be carried out:
Verification of the presence of any ventilation opening, ensuring it is free from obstructions
General inspection of the chimney
Verification of the tightness (seal) test, certified by the chimney installer
Verification of the required safety distances, certified by the chimney installer
Materials used and their compatibility with the installation site
Installation criteria for the flue duct, chimney, and any collector
Chimney terminals and outlet heights
Internal and external condition of the chimney, for example through video inspection using a rotating-head camera compliant with UNI 10847
For chimneys without previous inspections, certifications, or identification plates, the installer is responsible for their certification.
After the installation of the generator and at each maintenance intervention, the combustion process of the generator must be checked and adjusted in order to prevent environmental pollution.
Checks for manually loaded domestic generators, such as fireplaces, stoves, or wood-burning inserts, include:
Inspection of wood quality, verifying type, weight, and size in accordance with the manufacturer’s instructions
Fuel moisture content measurement in accordance with UNI 10389-2
Draft measurement in accordance with UNI 10389-2
Measurement of flue gas temperature
Verification of an adequate combustion air supply, for example by means of the 4-Pa test
Verification of smoke backflow in accordance with UNI 11859-1
Verification of the tightness of the coaxial exhaust system in accordance with UNI 11859-1