trasparente-per-sito-etc-2
cart-icon-png-graphic-cave
trasparente-per-sito-etc-2
icon png_for instagram pfoile
icon png_for instagram pfoile

ETC Group S.r.l. Sole Shareholder  

Industrial area Pirano, Tavullia

Str. Delle Campagne, 10

61010 Tavullia PU​ - ITALY

For truck route click Here 

 

Tel. 

+39 0721 1839937

+39 0541 955062
+39 0541 1646150​

WhatsApp-web +39 373 7755779

 

E-Mail DEPARTMENTS

informazioni@etcgroupsrl.biz

commerciale@etcgroupsrl.biz

​tecnico@etcgroupsrl.biz

contabilita@etcgroupsrl.biz

 

VAT and Tax Code: IT 04083110405

Reg. of companies of Pesaro  N. REA - PS – 196574

- Soot Scrubbers​

​- Hoods without Chimney

- Water-operated Hood 

​- Scrubbers for Wood-fired Ovens

- Scrubbers for Electric Ovens

- Scrubbers for Charcoal Grills

- Ozone Generators​

- Filters for Kitchen Hoods

- Stainless Steel Exhaust Fans

- Active Carbon Purifiers​

- Electrostatic Filters

- Boxed Exhaust Fans​

- Arturo Purifier

- Water Pump

- Privacy Policy

- Cookie Policy

- Hood with UV-C Lamps

 

What are the current regulations for exhaust fumes, odors on the wall 

In Italy, the current regulations for smoke and odor discharge on walls are contained in the following regulatory framework:

  • DPR 412/1993, amended by D.Lgs n. 102 of 2014, which governs the design, installation, and maintenance of heating systems.
  • UNI 7129:2015, which establishes the requirements for the installation of kitchen hoods.
  • UNI 10683:2017, which establishes the requirements for the design and installation of chimneys.

In particular, Article 5, paragraph 9, of DPR 412/1993, states that "The discharge of combustion products must occur on the roof: direct discharge on the wall or towards closed spaces, even open-air, is prohibited".

However, paragraph 9 bis of the same article provides some exceptions to this rule, allowing wall discharge in specific cases, including:

  • Systems installed before August 31, 2013: in this case, wall discharge is allowed if the system is still in use and if it is not possible or excessively burdensome to replace it with a roof system.
  • Systems with a power of less than 35 kW: in this case, wall discharge is allowed if the system is installed in a single-family home or an independent housing unit.
  • Systems with a power between 35 and 70 kW: in this case, wall discharge is allowed if the system is installed in a condominium and if a device for checking the airtightness of the discharge duct is provided.

In all cases where wall discharge is allowed, the following requirements must be met:

  • The discharge duct must be made of non-combustible material and must have a section not less than 150 cm².
  • The discharge duct must be equipped with a device for checking airtightness.
  • The discharge duct must be installed to prevent water infiltration.

Furthermore, it is necessary to obtain authorization from the Municipality before installing a system with wall discharge.

In conclusion, the current regulations for smoke and odor discharge on walls are very restrictive, and this type of discharge is allowed only in specific cases and only if the prescribed requirements are met.

 

 


 