Feature Value Filter height 50 cm Extractor height 44 cm Total height 94 cm Filter depth 56 cm Width 62 cm Cold water supply 1/2" Condensate drain to sewer 1" Inlet diameter Ø 150 mm Outlet diameter Ø 140-150 mm Feature | Value |
---|---|
Filter height | 50 cm |
Extractor height | 44 cm |
Total height | 94 cm |
Filter depth | 56 cm |
Width | 62 cm |
Cold water supply | 1/2" |
Condensate drain to sewer | 1" |
Inlet diameter | Ø 150 mm |
Outlet diameter | Ø 140-150 mm |
Technical Data Sheet
User Manual
HIGH TEMPERATURE
ASPIRATORS
+300°
Code. INOX.4.EBR280
ETC Group S.r.l. Sole Shareholder
Industrial area Pirano, Tavullia
Str. Delle Campagne, 10
61010 Tavullia PU - ITALY
Tel.
+39 0721 1839937
+39 0541 955062
+39 0541 1646150
WhatsApp-web +39 373 7755779
E-Mail DEPARTMENTS
informazioni@etcgroupsrl.biz
commerciale@etcgroupsrl.biz
tecnico@etcgroupsrl.biz
contabilita@etcgroupsrl.biz
VAT and Tax Code: IT 04083110405
Reg. of companies of Pesaro N. REA - PS – 196574
- Scrubbers for Wood-fired Ovens
- Scrubbers for Electric Ovens
- Scrubbers for Charcoal Grills
- Stainless Steel Exhaust Fans
1
2
VCTF UTABMP
Boxed fans with double suction and transmission, for medium-high pressures. Curved blades facing forward with respect to the direction of rotation.
Aluminum structure and insulation with sandwich paneling.
Belt-driven boxed fans, for medium-low pressures, with aluminum structure, insulation, and sandwich paneling.
VCTF BMP
Three-phase boxed extractors for low and medium temperatures.
TECHNICAL FEATURES:
USAGE RANGE
Flow rate: from 1,500 to 30,000 m³/h
Pressure: from 20 to 130 H2o
Construction of the box
The box is composed of a structure of oxidized aluminum extruded profiles P40 and corners in nylon reinforced with fiberglass and filled with sandwich paneling, with a thickness of 25 mm.
The internal and external support in pre-painted aluminum in white gray color, with a thickness of 0.5 mm
The interior, closed-cell expanded polyurethane foam (over 95%) density 47 kg /m³, thermal conductivity W/(m°C) 47+_2, acoustic insulation 40dB with extremely lightweight structure.
Maximum operating temperatures: -20°+70°C,
Inspection door on the transmission side with CE compliant closure complete with handle and fixing blocks.
Centrifugal fan with double reinforced transmission and mounted on rubber anti-vibration supports.
Three-phase asynchronous motor in 400V/50 Hz execution, IP 55 protection according to UNELMEC standards.
IE3 = Premium efficiency (new efficiency class in Europe today and identical to "NEMA Premium" in the United States for 60 Hz) according to IEC 60034-30, test methods IEC 60034-2-1.2007.
1 - Aluminum profiles 40 x 40 mm
2 - Omega aluminum profiles
3 - Sandwich paneling with a thickness of 25 mm with expanded polyurethane foam
with closed cells. Exterior and interior coated with aluminum sheet
with a thickness of 0.5 mm
APPLICATIONS
The VCTF UTABMP transmission boxed fans are filters designed for the filtration of solid pollutant particles (or particulate) present in the air flow in industrial air conditioning and HVAC systems, and in many applications in analysis laboratories, operating rooms, in the chemical and pharmaceutical fields.
Absolute filters are classified based on the filtration efficiency of the most penetrating particles according to the European standard EN 1822-1:2009
According to the latest version of the 1822 standard, the H13 filter requires a test on a single unit during production.
The H13 VariCel VXL filter is not tested individually, but has the efficiency value of class H13 99.95% MPPS.
The flow rates range from 1,500 m³/h to 30,000 m³/h and the static pressures range from 20 h2o to 130 h2o. The VCTFBMP series, using centrifugal fans with backward-curved blades, is characterized by high-level performance with advantageous efficiencies and low noise levels.
COMPARATIVE TABLE
MOD. | VENT. | Flow rate m³/h | Prevalence PA (RMP-KW) |
VCTFBMP | TDA SR 7/7 | 1.900 | 500-900-0.75 |
VCTFBMP | TDA SR 7/7 | 2.500 | 700 - 1200-1,1 |
VCTFBMP | TDA SR 9/9 | 3,000 | 600 - 1000-1,1 |
VCTFBMP | TDA SR 9/9 | 4.500 | 700 - 1200-1.5 |
VCTFBMP | TDA SR 10/10 | 5.000 | 600 - 1000-1.5 |
VCTFBMP | TDA SR 10/10 | 6.000 | 600 - 1300-2,2 |
VCTFBMP | TDA SR 12/12 | 6.500 | 700 - 900-2.2 |
VCTFBMP | TDA SR 12/12 | 8,000 | 600 - 950-3 |
VCTFBMP | TDA SR 15/15 | 9.000 | 600 - 750-3 |
VCTFBMP | TDA SR 15/15 | 11,000 | 700 - 650-4 |
VCTFBMP | TDA SR 18/18 | 15,000 | 600 - 650-4 |
VCTFBMP | TDA SR 18/18 | 16.000 | 800 - 650-5.5 |
VCTFBMP | TDA SR 20/20 | 20,000 | 500 - 650-5.5 |
VCTFBMP | TDA SR 25/25 | 30,000 | 500 - 650-7.5 |
VCTFBMP | TDA SR 30/20 | 40,000 | 500 - 650-11 |
STRUCTURE OF THE EXTRACTOR
▪ Supporting structure with frame and aluminum profiles. The box is composed of a profiled aluminum frame and filled with 25 mm thick sandwich paneling, internal and external support in pre-painted aluminum in white-gray color, 0.5 mm thick, closed-cell polyurethane foam (over 95%) density 47 kg /m³ thermal conductivity W/(m°C) 47+_2 acoustic insulation 40 dB with extremely lightweight structure weight.
▪ The fan is mounted on rubber anti-vibration supports to isolate the structure and the system from any type of vibration.
▪ Inspection door on the transmission side with CE standard closure.
The Table is for quick reference only.
For more precise data and for the correct selection of the model, consult the performance curves.
Variants of extractors with different powers can be assembled for optimal performance.
It is recommended to leave a tolerance of 10% - 15% in the calculation of flow rate and head to be closer to the
real data of the graphs.
Curves and technical features of fan TDA 7/7
FANS
Double inlet centrifugal fans, scrolls and frames made of galvanized steel sheet, with backward curved blades impellers in treated and epoxy painted steel. Sealed, self-aligning bearings with eccentric locking collar. Their minimum theoretical lifespan with standard mounted transmissions and proper maintenance is 30,000 hours.
MOTORS
Three-phase asynchronous motor in 400V/50 Hz execution, IP 55 protection according to UNEL-MEC standards. IE3 = Premium efficiency (new efficiency class in Europe today and identical to "NEMA Premium" in the United States for 60 Hz) according to IEC 60034-30 test methods IEC 60034-2-1.2007. Installed with 2, 4, or 6 poles depending on the required transmission. The mounting is on a stainless steel 304 frame welded on all sizes, and all models are equipped with a belt tensioner slide.
- Minimum fluid temperature: -20°C.
- Maximum fluid temperature: +60°C.
ACCESSORIES
- Rainproof roof.
- Exhaust pipe with protective net on the outlet.
- Filter holder pipe in ductable version.
- Inverter speed regulator.
- Support feet.
- External air intake grille.
- Adjustment damper
- Electrical panel compliant with inverter standards.
- ON/OFF switch.
- Pressing and suction silencer. Lock with key.
- Elle extractor supports in stainless steel 304
VCTF UTAMAP
Air purifiers for clean rooms and laboratories
TECHNICAL FEATURES:
USAGE RANGE
Flow rate: from 500 to 100,000 m³/h
Pressure: from 200 to 1300 Pa
Extremely quiet
CONSTRUCTION OF THE BOXED FAN
The boxed fan type VCTF UTAMAP is composed of a structure of oxidized aluminum extruded profiles P40 and corners in fiberglass-reinforced nylon, sealed with sandwich paneling 25 mm thick.
Internal and external support in pre-painted aluminum, white-gray color with a thickness of 0.5 mm.
The interior is coated with closed-cell polyurethane foam (over 95%) with a density of 47 kg/m³ and thermal conductivity W/(m°C) 47+_2. Acoustic insulation 40 dB with extremely lightweight structure weight.
Maximum operating temperatures: -20° +70°C
Inspection door on the transmission side with CE standard closure
Complete with handle and fixing blocks. Centrifugal type fan with double reinforced transmission and
mounted on rubber anti-vibration supports.
Three-phase asynchronous motor in 400V/50 Hz execution, IP 55 protection according to UNELMEC standards. IE3 = Premium efficiency (the new efficiency class today in Europe and identical to "NEMA Premium" in the United States for 60 Hz) according to IEC 60034-30 test methods IEC 60034-2-1.2007.
APPLICATIONS
The VCTF MAP belt-driven boxed fans are used for extraction with air duct systems and to reduce the noise of the systems, used in the industrial and civil plant engineering sectors.
The VCTF MAP series fans are to be used with medium-low flow rates and pressures. They have very low noise levels and are suitable for handling clean or slightly dusty air.
The flow rates range from 500 m3/h to 100,000 m³/h and the static pressures range from 500 Pa to 1900 Pa.
The VCTF MAP series, using centrifugal fans with backward-curved blades, is characterized by high-level performance with advantageous efficiency and low noise levels.
COMPARATIVE TABLE
STRUCTURE OF THE EXTRACTOR
▪ Supporting structure with frame and aluminum profiles. The box is composed of a profiled aluminum frame and filled with sandwich paneling, 25 mm thick, with internal and external pre-painted aluminum support in white-gray color, 0.5 mm thick, closed-cell polyurethane foam (over 95%) density 47 kg/m³
thermal conductivity W/(m°C) 47+_2 acoustic insulation 40 dB with extremely lightweight structure weight.
▪ The fan is mounted on rubber anti-vibration supports to isolate the structure and the system from any type of vibration.
▪ Inspection door on the transmission side with CE standard closure.
FANS
Double inlet centrifugal, scrolls and frames made of galvanized steel sheet, with backward curved blades impellers in treated and epoxy painted steel. Sealed bearings, self-aligning and shaft locking with eccentric ring. Their minimum theoretical lifespan with standard mounted transmissions and proper maintenance is 30,000 hours.
MOTORS
Three-phase asynchronous motor in 400V/50 Hz execution, IP 55 protection according to UNEL-MEC standards. IE3 =
Premium efficiency (new efficiency class in Europe today and identical to "NEMA Premium" in the United States for
60 Hz) according to IEC 60034-30 test methods IEC 60034-2-1.2007. Installed at 2, 4, or 6 poles depending on the
required transmission. The mounting is on a 304 stainless steel frame welded on all sizes, on all models the belt tensioner slide is mounted.
- Minimum fluid temperature: -20°C.
- Maximum fluid temperature: +60°C.
The Table is for quick reference only.
For more precise data and for the correct selection of the model, consult the performance curves.
Variants of extractors with different powers can be assembled for optimal performance.
It is recommended to leave a tolerance of 10% - 15% in the calculation of flow rate and head to be closer to the actual data of the graphs.
Curves and technical features of TLZ fan
ACCESSORIES
- Rainproof roof.
- Exhaust stub with protective net on outlet.
- Filter holder stub in ductable version.
- Inverter speed regulator.
- Support feet.
- External air intake grille.
- Adjustment damper
- Electrical panel compliant with inverter standards.
- ON/OFF switch.
- Pressing and suction silencer. Lock with key.
- Stainless steel 304 elle extractor supports